LBSA possesses an outstanding instrument base that includes

Atomic Force Microscopy (AFM)

Cantilever Sensor

Confocal Microscopy

Contact Angle Measurement

Differential Scanning Calorimeter (DSC)

Molecular Force Probe (MFP)

PriorLux Polarised Light Microscope

Quartz Crystal Microbalance (QCM)

Scanning Thermal Microscopy (SThM)

Spex 6870 Cryomill

Surface Plasmon Resonance (SPR)

Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) and X-ray Photoelectron Spectroscopy (XPS)

Biorad FTS6000

Nicolet InspectIR™ Plus

and many others.

LBSA also devotes significant effort to development of novel instruments including Cryogenic AFM, Optical Tweezers, Biomembrane Force Probe, Polarization Modulation Infrared Reflection Absorption Spectroscopy, etc.

High-performance graphics workstations and high-end computers linked via ultra-fast interconnect provide an excellent base for computer simulations in molecular dynamics study.

Research projects are supported by committed funds of £3.5M from BBSRC, EPSRC and industries.

 

Atomic Force Microscopy

We have a wide range of state-of-the-art Atomic Force Microscopes in the laboratory, providing high-quality surface imaging and analysis for various biomolecular and pharmaceutical applications. The following are a few highlights.

 

afmjeff
 
  • MultiMode 8 Scanning Probe Microscope (Veeco Instruments) This latest MultiMode AFM features two new technologies from Veeco, ScanAsyst™ and PeakForce™ QNM™. The PeakForce tapping mode of ScanAsyst™ provides a direct force control with minimum peak force down to less than 100pN, a level never achieved by previous AFM modes. Together with an automatic and dynamic parameter adjustment, MultiMode 8 SPM has made high-resolution imaging of delicate samples in both air and liquid environments achievable. Furthermore, simultaneous high-resolution and well-defined force mapping can be obtained by PeakForce™ QNM™ (Quantitative Nanomechanical Measurement).
 
  • ICnano® (ionscope) The Hopping Mode SICM (Scanning Ion Conductance Microscopy) offers imaging of immersed targets with zero force, an ideal technique for high resolution topographic imaging of living cell membranes and any soft or fragile surfaces immersed in electrolyte, with almost any size and shape of feature up to 100µm in height.

 

forcerobot300
 
  • ForceRobot® 300 (JPK Instruments) This latest fully automated molecular force spectroscope also provides the highest flexibility. Users can design complex experimental details (fluids, temperatures, force ramp parameters, etc.) of unlimited number of force measurement in advance and leave the instrument to complete the job automatically.
 
  • nano-TA2™ (Anasys Instruments) The new generation of thermal probes can image the sample of interest with sub-30nm spatial resolution (in contact or intermittent contact modes) and identify the regions to perform Localized Thermal Analysis, similar to DSC (Differential Scanning Calorimetry) measurement but localized to a surface area less than 100nm in diameter.

 

escope (left) and D31000 AFMs installed in LBSA
 
  • EnviroScope Atomic Force Microscope (Veeco Instruments) This special AFM allows observation of sample properties under precise temperature and humidity control. In addition to this Dimension-based eScope AFM, we also have heating stages for our MultiMode AFM instruments.
 

ToP

Cantilever Sensor

 Cantiliver Sensor
 

Cantisens® Research installed in LBSA is designed to support leading edge scientific research and industrial application development giving users access to innovative Cantilever Sensor technology. Using customized chemical sensing layers, Cantisens® Research can be employed for a wide range of scientific and industrial applications.

Cantilever array used for multi-purpose detection

The stand-alone system offers parallel, label-free detection of up to eight different substances or biomolecular interactions. It combines a multi-purpose cantilever sensor platform with powerful measurement electronics and easy-to-use control and evaluation software.

More information about the instrument and the Cantilever Sensor technology can be found on the Concentris website .

 

ToP

Confocal Microscopy

Confocal
 

Leica TCS SP confocal microscope is installed in LBSA. In contrast with the conventional wide-field fluorescence microscope, where the entire specimen is illuminated by a light source, a confocal microscope uses point illumination and a pinhole in an optically conjugate plane in front of the detector to eliminate out-of-focus information. Only the light within the focal plane can be detected, resulting in much better image quality than that of wide-field images.
Please see the Leica website for more information on confocal microscopy.

 

ToP

Contact Angle Measurement

Contact Angle Measure
 

Both micro and pico litre liquid contact angle measurements are routinely made within the LBSA. A KSV instrument is used to make the former measurements with manual dispensing and automated image analysis of the drop. The automated pico litre dispenser is used to make measurements on a length scale around one tenth of 1 mm and is fully automated. See, for example, Taylor, M.; Urquhart, A. J.; Zelzer, M.; Davies, M. C.; Alexander, M. R., Pico litre water contact angle measurement on polymers. Langmuir Letters 2007, 23, (13), 6875-6878.
Please see the KRÜSS website for technical details.

 

ToP

Differential Scanning Calorimeter

Q2000 Differential Scanning Calorimeter
 

The Q2000 Differential Scanning Calorimeter was delivered in mid 2009. This state of the art DSC has an automated sample change robot and a 50 sample magazine. It is capable of heating and cooling rates from 0.1 to 200 C per minute, and can run in both standard and temperature modulated modes, as well as quasi-isothermal. It stores up to 10 calibrations and is ideal for high-throughput, high precision measurements of the thermal properties of materials from -40 to 600 C. Typically, around 1 mg of sample is required.

 

ToP

Molecular Force Probe

Dr Green works with an MFP
 

We have two MFP-1Ds in the Laboratory. The MFP-1D is a single axis force curve tracer designed specifically for soft samples and has set the industry standard for picoNewton force measurements. The technology is based around a micro-machined flexible cantilever with a sharp tip that deflects in response to the small forces between the cantilever tip and a sample. Molecular Force Probe (MFP)

One of the MFPs is also combined with a Nikon TE300 ECLIPSE, achieving simultaneous molecular force measurements and fluorescence imaging. 

For more details about MFP-1D, please see Asylum Research's webpage .

ToP  

PriorLux Polarised Light Microscope

The PriorLux polarised light microscope operates in transmission and is equipped with a Linkam DSC600 hot-stage .  It was installed in late 2009. It allows simultaneous recording of a polarised optical video and a DSC trace. It is routinely capable of a temperature range -196 to 600 C. It requires only microscopic amounts of sample for optical measurements, and around 1 mg for concomitant DSC characterisation. It is used as a powerful complementary tool to the Q2000 DSC.

ToP

Quartz Crystal Microbalance    

Xiao, a research student in LBSA, works with QCM-DQuartz Crystal Microbalance (QCM)

The QCM-D (Quartz Crystal Microbalance with Dissipation monitoring) is based on a technology developed by Q-Sense by collecting both the dissipation and the resonance frequency of a quartz crystal.  It can be used to study t he formation of thin films such as proteins, polymers and cells onto surfaces in liquid.

Technical details of QCM-D can be found on the Q-Sense website .

 
 
 

ToP

Scanning Thermal Microscopy

nano-TA2
 

If the normal solid sharp probe used in AFM is replaced with a ultra miniaturised resistance, the imagScanning Thermal Microscopy (SThM)e contrast reflects variations in thermal properties across the sample surface. The probe can be used as either a micro-thermometer to obtain a temperature "map", or a highly localised heater to obtain a conductivity/diffusivity "map" of the sample surface. This equipment can also be used to measure localized thermal transitions, similar to the measurement done by the traditional DSC but in a very small surface domain.

In addition to the old generation of SThM with a micro-thermal probe attached to one of our Explorer AFMs, the new nano-TA2 from Anasys Instruments has also installed on one of our MultiMode AFMs. The proprietary thermal probes used in nano-TA2 can achieve scanning thermal microscopy and local thermal analysis with sub-100 nm resolution.

 

ToP

Spex 6870 Cryomill

Spex 6870 Cryomill
 

The Spex 6870 cryomill  is used to mill materials at liquid nitrogen temperature, and was commissioned in late 2009. It is used to produce a wide range of amorphous materials, up to 100 g. Milling renders materials amorphous, and the low temperatures prevent thermally-driven recrystallisation. We also have a Retsch MM400 mixer ball mill  (not shown) which operates at room temperature and is complementary to the cryomill.

Surface Plasmon Resonance

Surface Plasmon Resonance (SPR)
 

Surface Plasmon Resonance (SPR) allows sensitive detection of molecular interactions in real time without the use of labels. This saves the work of purifying and labeling material, and eliminates the risk that labels may interfere with the interaction being studied. Biacore 3000 is the highest performance research system available for label-free studies of biomolecular binding.

Please see Biacore's webpage for specification details of Biacore 3000.

ToP

Time of Flight Secondary Ion Mass Spectroscopy and X-ray Photoelectron Spectroscopy

ToF-SIMS
 

The state-of-the-art Time of Flight Secondary Ion Mass Spectrometer (ToF-SIMS) IV (ION-TOF GmbH , Münster, Germany) is equipped with a liquid metal (Bi) ion gun (LMIG) for spectroscopy and chemical imaging. In addition, an electron impact ion source allows spectroscopy using polyatomic primary ions and depth profiling using either C60+ or Cs+ (combined with crater analysis using the LMIG or C60+). emda logo 1The reflectron ToF mass analyser has a mass resolution in excess of 10,000. Recent upgrades to the instrument have been funded by The East Midlands Development Agency (emda) New Dimension in Health Care Analysis Project. This equipment is available for industrial access through the funding provided by emda .

Full temperature control of the sample in the analysis position over the range from −100 to +600°C is possible, including temperature programmed SIMS, and samples can be cooled in an inert atmosphere prior to insertion into the instrument. The 5-axis multisample stage is fully automated and provides rotation for high resolution depth profiling. Further details can be found at the ToF-SIMS website .

 

 

Krato Axis Ultra XPS
 

The state-of-the-art Kratos Axis Ultra XPS (installed in the School of Chemistry) is one of only a few such systems worldwide. Equipped with a monochromated Al K-alpha X-ray gun, Dual anode Al/Mg X-ray gun, UV lamp and delay-line detector, as well as advanced charge compensation and sample handling, this system is capable of recording very high energy resolution spectra as well as imaging at high spatial resolution. It is fully equipped for depth analysis.

Temperature control and sample handling similar to the SIMS is also available, making these systems ideal to combine the strengths of both analytical techniques.

 

ToP

Biorad FTS6000

 

 

The FTS 6000 Spectrometer is a high performance research grade multi-range FT-IR spectrometer capable of both rapid scan and step scan operation, covering the spectral range 11,000-400 cm-1. Its high quality 60o Michelson air bearing piezoscan interferometer features piezoelectric-based continuous dynamic alignment (which simultaneously maximizes the spectral throughput and minimizes the noise in their measurements) and a KBr beamsplitter beamsplitter for the mid IR. It is equipped with both MCT and DTGS detectors. By using a high wattage water-cooled ceramic source for the mid IR and a two-inch clear aperture through the interferometer, it focuses more than 150 mW of infrared power at the sample which is typically more than four times higher than systems based on air-cooled sources. It also utilises a patented in-scan co-adding (providing effective 22 bit A/D operation). The result is excellent signal-to-noise performance for low energy applications and enhanced sensitivity.

 

 

Nicolet InspectIR™ Plus

This FTIR attachment instrument employs external reflection, micro-ATR equipped using a silicon crystal. It is interfaced with a Nicolet Avatar 360 spectrometer and uses a liquid nitrogen cooled MCT detector. It is very useful for analysing solids, finding application in our group in pharmaceuticals.

This FTIR attachment instrument employs external reflection, micro-ATR equipped using a silicon crystal. It is interfaced with a Nicolet Avatar 360 spectrometer and uses a liquid nitrogen cooled MCT detector. It is very useful for analysing solids, finding application in our group in pharmaceuticals.

ToP

School of Pharmacy

University of Nottingham
University Park
Nottingham, NG7 2RD

telephone: +44 (0) 115 951 5100
fax: +44 (0) 115 951 5102
email: pharmacy-enquiries@nottingham.ac.uk