Second Registrar Review

Digit Clock 21
Digit Clock 4
Digit Clock 5
Digit Clock 9

Requirements for

Click on the items on the left to view the requirements and assessment of 's current situation as at the given time above. Select a different clock for information specific to that review time.

Noradrenaline was started at 21:20 with instructions to aim for:

  • MAP of 70 mmHg
  • Urine output of 35 mls/hr
    (patient weight estimated as 70 kg)
  • CVP is 10-12 mmHg

After 6 hours of receiving noradrenaline:

  • is on 10 mls/hr of noradrenaline
  • MAP is 65 mmHg
  • Urine output 15 mls/hr
  • CVP is 7 mmHg

N/A.

Urine output has increased to around 15 mls/hr – expected rate should be around ½ ml/kg – around 35 mls or more.

N/A.

Red Cross

is not improving quickly - she requires more fluid to bring the CVP up.

Next Previous Toolbar